An induction heater has few moving parts, so it is easy to forget about it until it stops. Water, moisture, dust and loose connections are common causes of stops. All four are cheap to check. This guide gives a routine you can adapt to your plant and your machine manual.
Always isolate and lock out the power supply before you open the cabinet or touch the coil connections. Work inside the cabinet is for qualified electrical personnel only.
Know your cooling water specification
Write the figures for your model on the machine and in your maintenance plan.
| Series | Cooling water pressure | Example model and minimum flow |
|---|---|---|
| CX | 0.1–0.15 MPa | CX2030C: 1.0 m³/h |
| SWS | 0.2–0.3 MPa | SWS-120A: 8.2 m³/h |
| MFS | 0.2–0.3 MPa | MFS-500A: 34 m³/h |
| SWP | See the machine manual | — |
Keep the inlet water temperature at or below 35 °C.
Pressure that is too low means not enough flow through the narrow paths in the power devices and capacitors. Pressure above the range can stress hoses and fittings. Hold the pressure inside the stated range.
Water quality
Use a closed circulating system with a pump, tank and cooling tower or heat exchanger. Once-through tap water or well water brings in minerals and dirt with every litre.
- Fill with clean, soft water. Hard water forms scale. Scale reduces flow and insulates the surface it coats, so components run hotter even when the gauge reads normal.
- Follow the water quality limits in your machine manual.
- Keep the tank covered and clean. Leaves, dust and insects in an open tank end up in the strainers.
- Clean strainers and filters on a fixed schedule, more often in dusty plants.
- Watch for rust or oil in the water. Either one means something is leaking into the circuit or corroding.
Daily checks (operator)
- Water pressure within range and every return flowing before power-on
- No leaks at the coil, hoses or cabinet
- No new alarms in the log
- Coil clean, turns not touching, no visible damage
- Cabinet doors closed and filters in place
Weekly or monthly checks (maintenance)
- Clean or replace cabinet air filters. Blow out dust from the cabinet with dry, oil-free air while the machine is isolated.
- Check tightness of busbar, output and coil connection bolts. Look for heat discolouration.
- Inspect the capacitor bank for bulging, leaks or overheating.
- Check flow on each water branch. A blocked branch can overheat one part while the main gauge looks normal.
- Clean the cooling tower or heat exchanger. A fouled exchanger lets the inlet temperature climb.
- For hardening machines: check the spray ring holes and the quenchant condition.
- For machines with handling systems: lubricate conveyors and moving parts to the maker’s schedule.
Seasonal care
Humid and rainy seasons
Moisture on electrical parts causes tracking, earth faults and burned components.
- Keep the machine in a dry, ventilated room. Do not install it where rain or washdown water can reach it.
- Watch for condensation. If the cooling water is colder than the dew point of the air around the machine, water condenses on pipes, busbars and boards inside the cabinet. This is common in humid climates when a chiller is used. Keep the water temperature above the dew point in humid weather, and check inside the cabinet for droplets after a stop.
- After a long shutdown in humid weather, open the cabinet and check for moisture before you power up.
Hot season
Summer brings more faults from high water temperature, scaling and blocked water paths.
- Check that the inlet water stays at or below 35 °C during the hottest part of the day, not only in the morning.
- Clean the cooling tower and heat exchanger before the hot season starts.
- Descale if flow has dropped.
Cold season
Water that freezes inside the coil, hoses or cooled components will crack them.
- When the ambient temperature can fall below 0 °C, add antifreeze to the circulating water, or drain the system completely during shutdowns.
- Check that the antifreeze type is acceptable for your machine and water circuit.
- Protect outdoor pipes and the cooling tower.
Dust and the machine room
Dust carries metal particles and moisture. On boards and busbars it forms leakage paths.
- Keep the machine room clean, especially in forging and grinding areas.
- Keep cabinet filters in place and clean.
- Do not store scale, chips or coolant drums next to the power cabinet.
Coil care
The coil is the part closest to heat, water and the workpiece, and it wears.
- Check the coil-to-part gap at each changeover. A coil that has moved changes the heating pattern.
- Look for damage: cracked or flattened turns, worn insulation, arcing marks and water leaks.
- Clean scale and spatter from between the turns. A bridge between turns shorts them.
- Keep a record for each coil: date into service, repairs, reshaping and the test results it gives. Retire coils that drift.
- Handle flux concentrators carefully. Laminated concentrators need their insulation restored after reshaping. Ferrite pieces are brittle.
- Store spare coils dry and protected. Drain their water first if there is any risk of frost.
Keep a maintenance log
Record each check, reading and repair. Water pressure, flow and inlet temperature logged daily will show a fouling problem weeks before it trips the machine. The log also gives the service engineer the history they need if a fault does occur.
Send us the drawing, material and target case depth, and our engineers will recommend a frequency and power.
Sources
- JKZ product page: CX2030C — CX cooling water pressure 0.1–0.15 MPa; flow at least 1.0 m³/h
- JKZ product page: SWS-120A — SWS cooling water pressure 0.2–0.3 MPa; flow at least 8.2 m³/h
- JKZ product page: MFS-500A — MFS cooling water pressure 0.2–0.3 MPa; flow at least 34 m³/h
- JKZ (old site): How to maintain the medium frequency induction heating machine with seasonal change — Moisture protection in wet seasons; inlet water not above 35 °C; antifreeze when ambient falls below 0 °C; clean the water tank
- JKZ (old site): Precautions for high frequency induction heating equipment and quenching machine tools — Check water flow and pressure in each circuit before operation; keep connecting bolts tight; clean the room
- JKZ (old site): Interpreting common issues with induction heating power supply — Scale or blockage in capacitor water paths causes overheating; circulating systems with pump, cooling tower and tank
- JKZ (old site): Quality control of induction hardening — A record for each inductor; magnetic concentrator repair; PAG quenchant checks by cooling curve