IGBT induction power supply trips or loses output: first checks before calling service

A safe order of checks when an IGBT induction heater trips or loses power: cooling water, mains supply, coil and load matching, connections.

Updated 1 October 2026 · 6 min read

An induction heater that stops mid-shift costs output fast. Many stops have a simple cause outside the electronics: water, supply, coil or a loose connection. Work through these in order before opening the power cabinet. Many faults are cleared at this stage, and the rest are much faster to fix when you can give the service engineer clear readings.

Safety first

Inside an induction power supply there are high voltages, large currents and stored energy in capacitors.

  • Only qualified electrical personnel should work on the power supply, the capacitor bank or the output transformer.
  • Isolate and lock out the mains supply before touching anything inside the cabinet or at the coil connections. Switching off the control panel is not isolation.
  • Wait for stored energy to discharge. Follow the waiting time and test procedure in your machine manual. Prove dead with a meter before you touch.
  • Do not bypass a protection to get the machine running. A trip is the machine protecting the IGBT modules and capacitors.
  • Remember that the coil and parts can be hot, and water may be at pressure.

Everything below that involves the inside of the cabinet assumes these steps have been taken.

Step 1: Record what happened

Before resetting, write down:

  • The alarm or fault message on the display
  • What the machine was doing: start of cycle, during heating, at the end of a long run
  • Which coil and which part were in use
  • Whether the fault repeats after one reset, and how soon

A trip at start-up points to a different cause than a trip after an hour of running. Do not keep resetting a repeated fault.

Step 2: Cooling water

Water is the most common cause of trips and of damaged components. The power devices, capacitors, busbars and coil all depend on it.

Check against the specification for your model:

Series Cooling water pressure Example flow (minimum)
CX 0.1–0.15 MPa CX2030C: 1.0 m³/h
SWS 0.2–0.3 MPa SWS-80A: 5.5 m³/h
MFS 0.2–0.3 MPa MFS-250A: 17 m³/h

Your machine nameplate and manual give the exact figure for your model.

Then check:

  • Inlet temperature. Keep the inlet water at or below 35 °C. In hot weather a cooling tower or heat exchanger that is too small, or fouled, will let it climb.
  • Flow from each return. If your machine has open return lines or flow indicators, check that every circuit is flowing. One blocked branch can overheat one capacitor or one coil while the main gauge looks normal.
  • Scale and debris. Scale builds up in narrow water paths. It reduces flow and insulates the surface it coats. Hard water and open systems make it worse.
  • Hoses. Look for kinks, collapsed hoses and leaks, especially at the coil, where hoses move.
  • Flow or pressure switch. If water is clearly fine but the alarm stays, the switch itself may be faulty. Have it tested rather than bridged.

Step 3: Mains supply

  • Voltage. The three-phase CX, SWS and MFS models are specified for 380 V ±10%, 50/60 Hz. That means the supply should stay between 342 V and 418 V under load. The CX2015A and CX2020A use single-phase 220 V ±10%. SWP models are rated for three-phase 380 V; check the tolerance in your manual. Measure at the machine terminals, with the machine running if it is safe to do so.
  • Phase loss. A blown fuse or a loose phase connection upstream can trip the machine or cut output.
  • Breaker and cable size. Compare with the rated input current on the nameplate. For example, the MFS-250A is rated at 380 A input current and the SWS-80A at 125 A. An undersized feeder heats up and the voltage sags when the machine loads up.
  • Other loads on the same feeder. Large motors or welders starting on the same supply can cause dips.

Step 4: Coil and load matching

The power supply and coil form a resonant circuit together with the part. The control tracks the resonant frequency. If the load moves too far from what the machine was set up for, the supply cannot deliver full power, or it trips.

Check:

  • Is this the right coil for the part? A coil made for a larger part, or used with the wrong part, changes the load.
  • Coil-to-part gap and centring. A larger gap means weaker coupling and lower power into the part. A part touching the coil can short turns and trip the machine.
  • Empty coil. Running with no part, or a part that has fallen out of position, changes the load.
  • Coil damage. Look for flattened or cracked turns, burned insulation, water leaks and spatter or scale bridging between turns.
  • Changes in the job. A new part size or material, or a change from cold to hot start, shifts the load. Magnetic steel changes behaviour above the Curie point.

Low output with no alarm is often a matching issue. The heater runs, but the part takes longer to reach temperature or does not reach it.

Step 5: Connections

With the power isolated and proven dead:

  • Check bolts on busbars, output terminals and coil connections for tightness.
  • Look for discolouration, burned paint or melted insulation near joints. A loose high-current joint heats up and gets worse with time.
  • Check the capacitor bank for bulging, leaks or signs of overheating, and check the insulation of the capacitor mounting.
  • Check that control cable plugs are fully seated.
  • Clean dust from the cabinet. Conductive dust and moisture can cause tracking and earth faults.

Uneven heating is not always the power supply

If parts come out hotter on one side, check coil design, part position in the coil and the frequency for the job before suspecting the supply. A stable supply cannot correct a part that sits off-centre.

When to call service

Stop and contact service when:

  • The same alarm returns after the water, supply, coil and connection checks are clean
  • You see smoke, smell burning, or find burned or cracked components
  • An IGBT module, driver board, control board or capacitor may be damaged
  • The fault involves anything inside the cabinet beyond what your maintenance procedure allows

JKZ’s after-sales service covers fault diagnosis and maintenance, with online or on-site operator training. To speed things up, send the model and serial number, the alarm message, photos of the display and any damage, your water pressure, flow and temperature readings, your voltage readings, and a description or drawing of the coil and part.

Send us the drawing, material and target case depth, and our engineers will recommend a frequency and power.

Sources

  1. JKZ product page: CX2030C — 3 phases 380 V ±10% 50/60 Hz; cooling water pressure 0.1–0.15 MPa; flow at least 1.0 m³/h
  2. JKZ product page: CX2015A — 1 phase 220 V ±10% 50/60 Hz (CX2020A page gives the same supply)
  3. JKZ product page: SWP-MT series — SWP input voltage given as AC 3P380V, no tolerance stated
  4. JKZ product page: MFS-250A — 3 phases 380 V ±10% 50/60 Hz; input current 380 A; cooling water pressure 0.2–0.3 MPa; flow at least 17 m³/h
  5. JKZ product page: SWS-80A — Cooling water pressure 0.2–0.3 MPa; flow at least 5.5 m³/h; input current 125 A
  6. JKZ (old site): How to maintain the medium frequency induction heating machine with seasonal change — Inlet cooling water not above 35 °C; scaling and blocked water paths cause summer faults
  7. JKZ (old site): Interpreting common issues with induction heating power supply — Scaled or blocked water paths overheat capacitors; capacitor insulation faults; uneven heating from coil design, part position and frequency
  8. JKZ (old site): The main components of induction heating machine — Rectifier, inverter, output transformer and coil, DSP control with phase-locked loop tracking and status monitoring
  9. JKZ (old site): Services — After-sales fault diagnosis, maintenance and training

Send us your part.

We reply within 1 working day.

Our timeUTC+8

[email protected]+86-28-84211110