Before you ask for a quote, it helps to know roughly how much power the job needs. A short calculation gives you a first estimate. It tells you whether you are looking at a 100 kW machine or a 500 kW machine, and it lets you check any quote you receive. It does not replace a proper sizing from the drawing.
The basic formula
For through-heating, the power that must reach the part is the heat it absorbs, divided by the time available. The power drawn by the machine is larger, because not all of it reaches the part:
P ≈ m · c · ΔT / (t · η)
| Symbol | Meaning | Unit |
|---|---|---|
| P | Output power of the induction heater | kW |
| m | Mass heated in time t | kg |
| c | Average specific heat of the material over the temperature range | kJ/(kg·K) |
| ΔT | Final temperature minus starting temperature | K (same size as °C) |
| t | Time available to heat mass m | s |
| η | Overall efficiency from heater output to heat in the part | 0 to 1 |
For a continuous line, m / t is simply the throughput. Convert it to kg/s by dividing kg/h by 3600.
The terms in more detail
Mass and time: m / t
Use the throughput you need at the press, plus margin for start-up and stops. If you heat one billet at a time, m is the billet mass and t is the heating time per billet.
Average specific heat: c
This is where many quick estimates go wrong. The specific heat of steel is not constant. It rises with temperature and shows a sharp peak at the magnetic transition (the Curie point). Iron also changes crystal structure at higher temperature, which absorbs extra energy.
Using the room-temperature value gives an answer that is too low. For pure iron:
- At 25 °C, the specific heat is 25.094 J/(mol·K). With a molar mass of 55.845 g/mol, that is 0.449 kJ/(kg·K).
- From the NIST-JANAF tables, the enthalpy rise of iron from 25 °C (298.15 K) to 1227 °C (1500 K) is 45.643 kJ/mol. That is 45.643 ÷ 0.055845 = 817 kJ/kg.
- Spread over the temperature rise of 1201.85 K, the average specific heat is 817 ÷ 1201.85 = 0.68 kJ/(kg·K).
- The same calculation to 1127 °C (1400 K) gives 42.033 ÷ 0.055845 ÷ 1101.85 = 0.68 kJ/(kg·K).
So between room temperature and about 1100–1230 °C, an average of about 0.68 kJ/(kg·K) is a fair figure for iron. The room-temperature value of 0.449 is about 34% lower. An estimate built on it would be about a third short.
Carbon and alloy steels differ from pure iron somewhat. For a first estimate, the iron figure is a reasonable start. For alloy steels, check the enthalpy data for your grade.
Temperature rise: ΔT
Use the actual starting temperature. Billets stored outside in winter start colder than billets in a warm shop. Use the temperature you need at the press, not at the coil exit, and allow for the cooling during transfer.
Efficiency: η
η covers everything between the heater output and the heat that stays in the billet:
- Coil efficiency. Part of the power heats the copper coil and is carried away by the cooling water. This depends strongly on coil design, the gap between coil and billet, and the ratio of billet diameter to reference depth. Efficiency rises quickly as that ratio increases up to about 4, so the frequency must suit the billet size.
- Heat losses from the billet. A billet at forging temperature loses heat by radiation and convection, especially near the coil exit.
- Losses in leads and the output transformer.
Coil efficiency is not a fixed number. It changes with material, diameter, frequency, coil design and temperature. This is why we do not quote a single “typical” value here, and why the final sizing must come from the actual part and coil.
Illustrative worked example
Illustrative calculation, not a JKZ test result. All inputs below are chosen for this example only. The efficiency values are assumptions to show how much they change the answer. They are not measured figures.
Job: through-heat carbon steel billets, 60 mm diameter, for forging.
- Throughput: 500 kg/h
- Start temperature: 25 °C
- Target temperature: 1200 °C (chosen for this example)
- Average specific heat: 0.68 kJ/(kg·K), from the iron data above
Step 1. Throughput in kg/s: 500 ÷ 3600 = 0.1389 kg/s
Step 2. Energy per kg: 0.68 × (1200 − 25) = 0.68 × 1175 = 799 kJ/kg
Step 3. Power into the billets: 0.1389 × 799 = 111 kW
Step 4. Heater output power for different assumed efficiencies:
| Assumed η | Heater output P = 111 ÷ η |
|---|---|
| 0.7 | 159 kW |
| 0.6 | 185 kW |
| 0.5 | 222 kW |
The spread is wide: from 159 kW to 222 kW for the same job. That is why efficiency has to be confirmed from the coil design, not guessed.
Step 5. Frequency check. JKZ’s reference guidance for through-heating bars of 50–80 mm diameter is 2–5 kHz. That falls inside the 1–8 kHz range of the MFS series. In this power range the MFS-160A, MFS-200A and MFS-250A are rated at 160, 200 and 250 kW. Which one fits depends on the real efficiency, the margin you want and the soak needed for a uniform core.
What the formula leaves out
- Core-to-surface temperature difference. Induction heats from the outside. Large billets need time for the heat to conduct to the centre. This can set the coil length and the minimum heating time, not only the power.
- Duty cycle and stops. If the line stops, billets in the coil must be held or removed. Plan for this.
- Scale loss. Heating time and temperature affect oxidation.
- Supply capacity. Check the input current of the machine against your plant supply.
What our engineers need for sizing
- Billet material, diameter or section, and length
- Throughput in kg/h or pieces per hour
- Start and target temperature, and allowed core-to-surface difference
- Available floor length for the coil line
- Plant supply voltage and capacity
Coil efficiency varies from job to job, so JKZ engineers confirm the final sizing from your drawing and process data.
Send us the drawing, material and target temperature, and our engineers will recommend a frequency and power.
Sources
- NIST-JANAF Thermochemical Tables: Iron (Fe), reference state — Enthalpy of iron H − H(298.15 K): 45.643 kJ/mol at 1500 K; 42.033 kJ/mol at 1400 K; Cp 25.094 J/(mol·K) at 298.15 K; magnetic and alpha-gamma transitions
- NIST Chemistry WebBook: Iron — Molar mass of iron 55.845 g/mol
- Wikipedia: Induction heating — Heating efficiency depends on the ratio of bar diameter to reference depth and rises quickly up to a ratio of about 4
- JKZ (old site): Induction heating frequency selection — Bar diameter 50–80 mm: 2–5 kHz for through-heating
- JKZ product pages: MFS series — MFS 1–8 kHz; models MFS-160A, MFS-200A and MFS-250A at 160, 200 and 250 kW